• Plate heat exchanger unit
Plate heat exchanger unit
+

Plate heat exchanger unit

Small steam‑powered rapid heat exchange units must be capable of immediately supplying stable‑temperature hot water when most employees turn on their taps at the same time, and maintain constant water temperature when some employees simultaneously shut off their taps. When a tap is first opened, excessive cold‑water discharge should not be required, and the water temperature must be safe to prevent scalding. The water quality must be hygienic; direct contact with industrial steam is prohibited, and long‑retention hot water should not be used. Heat exchangers should occupy minimal space in the equipment room, exhibit low scaling rates, require minimal maintenance, and feature unattended operation and alarm notification capabilities.

Contact Us

If you are interested in collaborating, please contact us today!




Anhui Plant: No. 26 Zhangcun Road, Langxi Economic Development Zone, Xuancheng, Anhui


Jiangyin Plant: No. 198, Zhongshan Road, Qiaoqi, Xu Xiakke Town, Jiangyin City, Jiangsu Province

Product Description

111

Compact Steam Rapid Heat Exchanger Unit

When most employees turn on the tap at the same time during a specific period, the system must be able to immediately supply hot water at a stable temperature.

In an instant, some employees might turn off the faucets simultaneously, so a constant water temperature is required.

When you first turn on the tap, there’s no need to let a lot of cold water run first.

The water temperature must be safe; hot water that could scald employees is not permitted.

The water must be sanitary; it must not come into direct contact with industrial steam, nor should hot water with a long residence time be used.

Heat exchange equipment should occupy minimal space in the machine room, exhibit low fouling rates, require minimal maintenance, and feature unattended operation with alarm notification capabilities.

 

Model number LZ-50-N- LZ-200-N- LZ-300-N- LZ-450-N- LZ-1200-N- LZ-800-N-
Heat Load (kW) 150 200 300 150 600 800
Heat source: saturated steam at 4 barg Flow rate (KG/H) 255.9 341.2 511.7 767.6 1023 1365
Steam pipeline 32 40 50 65 80 80
Condensate piping 20 20 25 32 80 40
Heat source: 95/70℃ high-temperature water Traffic 5.2 6.9 10.3 15.4 20.6 27.5
Takeover Specifications 40 50 50 65 80 80
Secondary side: Water 10/60℃ Traffic 2.6 3.4 5.2 7.7 10.3 13.8
Takeover Specifications 32 40 40 50 50 65
Overall dimensions Length * Width * Height 1700*800*850 1700*1000*850 1850*1000*920 1900*1200*980 1900*1200*980 2050*1400*1280

 

Model number LZ-1000-N- LZ-1200-N- LZ-1500-N- LZ-2000-N- LZ-2500-N- LZ-3000-N-
Heat Load (kW) 1000 1200 1500 2000 2500 3000
Heat source: saturated steam at 4 barg Flow rate (KG/H) 1706 2047 2559 3412 4265 5117
Steam pipeline 100 100 100 125 150 150
Condensate piping 40 50 50 50 65 80
Heat source: 95/70℃ high-temperature water Traffic 34.4 41.3 51.6 68.8 90.1 103.2
Takeover Specifications 100 100 125 125 125 150
Secondary side: Water 10/60℃ Traffic 17.2 20.6 25.8 34.4 43 51.6
Takeover Specifications 65 80 80 100 100 100
Overall dimensions Length * Width * Height 2050*1400*1280 2100*1500*1280 2100*1500*1280 2100*1600*1450 2100*1700*1600 2100*1700*1600

Air conditioning and heating heat exchanger unit

For air conditioning and underfloor heating systems (10°C temperature difference) Model number LZ-450-K/D- LZ-600-K/D- LZ-800-K/D- LZ-1000-K/D- LZ-1200-K/D- LZ-1500-K/D- LZ-2000-K/D-
Heat Load (kW) 450 600 800 1000 1200 1500 2500
Heat source: saturated steam at 4 barg Flow rate (KG/H) 767.6 1023 1365 1706 2047 2559 3412
Steam pipeline 65 80 80 100 100 100 125
Condensate piping 32 32 40 40 50 50 50
Heat source: 95/70℃ high-temperature water Traffic 15.5 20.6 27.5 34.4 41.3 51.6 68.8
Takeover Specifications 65 80 80 100 100 125 125
Secondary side: Water 10/60℃ Traffic 38.7 51.6 68.9 86.1 103 129 172
Takeover Specifications 100 100 125 125 150 150 200
Overall dimensions Length * Width * Height 2100*1650*1280 2100*1650*1280 2300*1900*1450 2300*1900*1450 2450*2150*1660 2450*2150*1660 2650*2250*1850

 

For air conditioning and underfloor heating systems (10°C temperature difference) Model number LZ-3000-K/D- LZ-4500-K/D- LZ-6000-K/D-

LZ-10000-K/D-

LZ-20000-K/D-

LZ-30000-K/D-

LZ-40000-K/D-

LZ-50000-K/D-

LZ-60000-K/D-

Heat Load (kW) 3000 4500 6000 10000 20000 30000 40000 50000 60000
Heat source: saturated steam at 4 barg Flow rate (KG/H) 5117 7676 10230 17060 34120 51170 68230 85290 102300
Steam pipeline 150 200 200 300 400 500 550 600 650
Condensate piping 65 80 100 100 150 200 250 250 300
Heat source: 95/70℃ high-temperature water Traffic 103 154 206 343.9 687.8 1032 1376 1719 2063
Takeover Specifications 150 200 200 250 350 400 500 500 600
Secondary side: Water 10/60℃ Traffic 258 387 516 862.6 1725 2588 3450 4313 5176
Takeover Specifications 250 250 300 400 500 650 700 800 900
Overall dimensions Length * Width * Height 2850*2350*1850 3300*2350*2080 3500*2350*2080 Customization Customization Customization Customization Customization Customization

 

For heating systems (25°C temperature difference) Model number LZ-450-N - LZ-600-K/D- LZ-800-K/D- LZ-1000-K/D- LZ-1200-K/D- LZ-1500-K/D- LZ-2000-K/D-
Heat Load (kW) 450 600 800 1000 1200 1500 2500
Heat source: saturated steam at 4 barg Flow rate (KG/H) 767.6 1023 1365 1706 2047 2559 3412
Steam pipeline 65 80 80 100 100 100 125
Condensate piping 32 32 40 40 50 50 50
Heat source: 120/80℃ high-temperature water Traffic 9.7 12.9 17.2 21.5 25.8 32.2 43
Takeover Specifications 50 65 65 80 80 100 100
Secondary side: Water 70/95℃ Traffic 15.4 20.6 27.5 34.4 41.3 51.6 68.8
Takeover Specifications 65 80 80 100 100 125 125
Overall dimensions Length * Width * Height 2100*1600*1240 2200*1750*1280 2200*1750*1280 2350*1950*1280 2350*1950*1450 2450*1950*1450 2650*2100*1660

 

For heating systems (25°C temperature difference) Model number LZ-3000-K/D- LZ-4500-K/D- LZ-6000-K/D-

LZ-10000-K/D-

LZ20000K/D-

LZ-30000-K/D-

LZ-40000-K/D-

LZ-50000-K/D-

LZ-60000-K/D-

Heat Load (kW) 3000 4500 6000 10000 20000 30000 40000 50000 60000
Heat source: saturated steam at 4 barg Flow rate (KG/H) 5117 7676 10230 17060 34120 51170 68230 85290 102300
Steam pipeline 150 200 200 300 400 500 550 600 650
Condensate piping 65 80 100 100 150 200 250 250 300
Heat source: 120/80℃ high-temperature water Traffic 64.5 96.7 129 213.8 427.6 641.3 855.1 1069 1283
Takeover Specifications 125 150 150 200 300 350 400 450 450
Secondary side: Water 70/95℃ Traffic 103 154 206 343.9 687.8 1032 1376 1719 2063
Takeover Specifications 150 200 200 250 350 400 450 500 550
Overall dimensions Length * Width * Height 2850*2350*1660 3200*2350*1850 3200*2350*1850 Customization Customization Customization Customization Customization Customization

 

Water, water-heat exchanger unit

Heat source for the heating unit

Non-standard units can prioritize using high-temperature wastewater for heat exchange, such as high-temperature steam condensate, with any shortfall supplemented by steam heating. This approach both reduces steam costs and saves on expenses associated with cooling and discharging wastewater.

Unit Control Instructions

The control system collects signals from the heat exchange unit, including primary and secondary side temperatures, pressures, differential pressure across the dirt separator, outdoor temperature, flow rates, and the manual/automatic and operating/fault statuses of the circulating and make-up pumps, and is capable of transmitting these
These signals are uploaded to the monitoring center via a remote terminal control system, enabling remote control. The controlled parameters include: secondary-side supply water temperature, pressure, and supply/return pressure differential.

Commonly Used Control Strategies

(1) The heat exchange unit features climate compensation and horizontal manifold water supply functionality.

The application programmable controller automatically sets the primary-side supply water temperature based on changes in outdoor temperature and the local heat load curve, and can also set a compensation value as required. The measured value of the secondary-side supply water temperature is compared with the setpoint,
Through PID control, the controller output signal adjusts the electric valve to regulate temperature.

(2) Automatic water replenishment

A pressure sensor installed on the secondary-side return pipe measures the pressure signal; after comparison with the setpoint, it outputs control commands to start or stop the make-up water pump or to adjust its speed via frequency conversion, thereby maintaining constant-pressure makeup.

(3) Automatic pressure relief function

The unit can select the hot water expansion overpressure within the Jin Xin buffer system of the pressure expansion tank.
Pressure relief can also be achieved using a waterproof solenoid valve;
To ensure absolute safety, both methods are equipped with safety valves.

(4) Secondary-side supply with return‑water differential pressure control: The return system requires a differential pressure bypass valve, typically installed between the distribution manifold and the collection manifold, or alternatively integrated into the heat exchange unit. Purpose: When the load decreases, the return pressure drops, causing the circulating pump to operate at a low flow rate. Frequent load fluctuations would lead to continuous changes in the pump’s operating condition, shortening its service life. In such cases, the differential pressure bypass valve, connected in parallel with the load, opens to maintain adequate water circulation throughout the system. On the other hand, without controlling the supply–return differential pressure, water tends to return preferentially from the terminal users; when these terminal users are operating at high loads, they may not receive sufficient flow.

Even with a differential pressure bypass valve installed, most users still opt for a variable-frequency circulation pump to enhance system stability. The differential pressure setpoint can be configured on the local controller or remotely.

(5) Power-off protection function

When a sudden power outage occurs, the motorized valve on the primary side automatically shuts off the heat source (e.g., steam) to prevent overheating or even vaporization on the secondary side, which could damage the heat exchanger and piping. The controller and variable frequency drive automatically reset, restoring all set parameters and
The operating parameters remain as they were before the power was cut.

(6) Power-On Self-Test Function

The secondary return water pressure is equipped with a preset over‑pressure protection threshold. When the secondary side pressure fails to reach this set value, the circulating pump cannot be started; only the make‑up water pump may be activated to replenish water. The circulating pump can be started only after the pressure has reached the set value for heat exchange.
After power is supplied to the unit, it performs a self-check and sequentially starts each module.

(7) Undervoltage Protection

When the secondary-side return water pressure falls below the set value, the circulating pump automatically stops running.

(8) Over-temperature protection

When the primary-side heat source temperature exceeds 180 degrees, the electric valve automatically closes and an alarm signal is triggered.

(9) Overpressure Protection

When the secondary water supply pressure exceeds the set value, in addition to automatic pressure relief, the primary-side electric valve is also closed.

(10) Monitor the water tank level

When the water tank level falls below the ultra-low limit, the make-up water pump stops and an alarm signal is issued.

(11) Time Control Program

It can schedule power on/off, features an energy-saving mode, and allows for time-of-day heating schedules on a daily, weekly, or monthly basis.

Keywords:

Plate heat exchanger unit

Previous

Next

Frequently Asked Questions

What materials can you use to make heat exchangers?

304/316L, TA1, SMO254, nickel, C276, etc.

Can you customize production according to my requirements?

Custom production is available upon request, e.g., interface dimensions, mounting type, material, etc.

What should you do if plate heat exchangers are prone to scaling and clogging?

For media prone to scaling and fouling, you can choose detachable plate heat exchangers, wide-channel plate heat exchangers, or Hybrid tubular straight‑channel heat exchangers. With a wide range of heat exchanger designs and technologies, our technical engineers will select a cost‑effective solution tailored to your specific operating conditions.

What is the pressure rating of the plate heat exchanger?

Typical removable plate heat exchangers can handle pressures up to 2.5 MPa; semi-welded plate heat exchangers can reach 6 MPa; standard all-welded units withstand 4.0 MPa; and plate-and-shell heat exchangers can tolerate pressures as high as 10.0 MPa. The choice should be based on a comprehensive assessment of operating conditions.

Which type of heat exchanger would be most suitable?

The selection of a heat exchanger depends on many factors. Our experienced technical engineers will design a heat exchanger of the appropriate size and specifications based on the data and requirements you provide, ensuring you receive a high-quality solution with excellent performance.

What data are required to calculate, select, and price a heat exchanger?

Please prepare the following data: fluid type, inlet and outlet temperatures on the cold and hot sides, flow rate, pressure, pressure drop, etc. The more complete the data you provide, the more accurate the equipment selection will be. Once the model and material are confirmed, the sales team will calculate the price and issue a quotation.

What certificates has the heat exchanger obtained?

The company has obtained professional certifications including ASME, pressure vessel, ISO 9001, ISO 14001, and ISO 45001. It holds 35 patented technologies, and its annual R&D expenditure remains at 4–5% of its output value.

Where is the production factory?

Jindabang currently operates two factories, located in Jiangyin, Wuxi, and Langxi, Xuancheng, Anhui, with a total site area exceeding 35,000 square meters, of which the Anhui facility occupies over 23,330 square meters.

全口种植牙怎么样,ALL-on-4又是什么?

医疗技术的进步飞速发展,种植牙领域也同样如此,全口缺牙一直是种植牙领域中的复杂困难病例,因为全口没牙,时间一久便会引起牙槽骨的全貌萎缩

牙齿矫正最佳年龄?几岁最好?

牙齿矫正可以帮助畸形和脱臼的牙齿立正,但一些成年人担心在矫正年龄增加后是否仍能矫正,一些顾客担心他们的孩子太小,一段时间内无法矫正,那么牙齿矫正最佳年龄是什么?

常见床垫故障排除——发霉

床垫在使用中塑料膜未拆除、铺板不透气、使用环境潮湿等情况可能会导致表面发霉。请保持室内空气畅通,时常换洗床单并清洁床垫表面。

常见床垫故障排除——长虫

床垫在使用中长期无翻动或不清洁,可能会滋生细菌及螨虫。请保持室内空气畅通,时常换洗床单并清洁床垫表面。

怎样保养床垫?

1、新购置的床垫因长时间密封包装,可能会有新品气味,只要保持室内空气流通或放置于通风阴凉处72小时,气味会明显降低。